For Android: 2.3 and up | Guide: Arc Flash Calculator Labeling cheats tutorial |
When updated: 2018-10-32 | Star Rating: |
Name: Arc Flash Calculator Labeling hack for android | Extension: Apk |
Author: ARCAD INC. | File Name: com.arcadvisor.arcflashanalytic |
Current Version: 1.0.2 | User Rating: Everyone |
Downloads: 5000- | Version: mod, apk, unlock |
System: Android | Type: Education |
Watch Arc Flash Studies Simplified video.
Watch Calculating Arc Flash Risk & Hazard To Enable Arc Flash Clothing Protection Selection video.
Watch Arc Flash Software, Arc Flash Labels video.
Watch Arc Flash Label Calculator Intro video.
Watch Arc Flash Incident Energy Calculations for 240 Volts or Less video.
Watch How to Perform an Arc Flash Study video.
Watch Available Fault Current Label 110.24 (15min:13sec) video.
Watch NEC 2011 Arc Flash Hazard Warning 110.16 (15min:45sec) video.
Watch SKM Arc Flash Tutorial Video video.
Watch Arc Flash Analysis Label Making Software Features video.
The Arc Flash Analytic tool has been developed based on IEEE 1584 Tutorial for Performing Arc-Flash Hazard Calculations as an simple to use and comprehensive program for calculating incident energy and arc flash boundary, for determining limited, restricted, prohibited approach boundaries and hazard risk category needed by NFPA 70E, NEC / CEC and OSHA when work is to be performed on or near the energized equipment. The IEEE 1584 empirically derived model was selected for arc flash analysis due to the model's capability to accurately acc for a wide dozens of setup parameters including: * begin and box equipment configurations * grounding of all types and ungrounded * gap between conductors of 3 to 152 mm. * short circuit currents in the range of 700A to 106kA * system line voltages in the range of 208V to 15kV * working distances from 10 to 80 inches For cases where voltage is over 15kV or gap is outside the range of the model, the theoretically derived Lee way can be applied and it is included in iAFA V1.0 The arc flash tool takes equipment configuration, gap between electrodes, grounding kind, short circuit fault current value and system voltage on input, and determines arcing fault current at potential point of fault. For protective devices operating in the steep portion of their time-current curves, a little change in current causes a large change in corresponding operating time. Incident energy is linear with time, and consequently arc current variations may have a large result on incident energy. The IEEE 1584 proposed solution is to create two arc current and energy calculations: one using the calculated expected arc current and other one using a reduced arc current that is 15% lower. The arc flash tool enables calculations for both of the above considered cases. The iAFA arc flash tool predicts arcing fault current for a given configuration and amount of the accessible 3-phase short circuit current. Next, the incident energy, arc flash boundary, shock safety boundaries and level of personnel protective equipment are determined based on equipment configuration, chosen upstream safety device ratings and working distance. Benefits: * Detailed analysis using the IEEE 1584 equations and the Lee way * Collect info, take images of switchgear, MCC's etc. during field walk-downs * Instantly determine arcing current, incident energy, arc flash, limited, restricted, prohibited approach boundaries, hazard risk category, typical clothing system * Add fuse and circuit breaker data including time-current characteristics for the devices that are not already featured in the built-in safety device library * Calculator-style interface makes complex calculations simple to understand * Provide a safer working environment by specifying the proper level of private protective equipment. Wearing inadequate clothing is risky for obvious reasons, but wearing too much clothing is risky due to limited mobility and visibility * Design safer power systems while insuring compliance with NEC 110.16, OSHA, NFPA 70E, IEEE P1584 and CSA Z462 standards and regulations * Avoid potential fines, lost productivity, and increased insurance and litigation costs * Set arc duration cut-off in the 2 to 10 second range * Evaluate Threshold Incident Energy for a Second Degree Burn * Generate arc flash warning labels in high resolution graphic format * Make warning labels in English and a dozens of international languages * Save input configurations, equipment photo for future reference * Send extended report including equipment data, calculation results, arc flash label * Perform analysis using metric, imperial troops
Share you own hack tricks, advices and fixes. Write review for each tested game or app. Great mobility, fast server and no viruses. Each user like you can easily improve this page and make it more friendly for other visitors. Leave small help for rest of app' users. Go ahead and simply share funny tricks, rate stuff or just describe the way to get the advantage. Thanks!
Welcome on the best website for android users. If you love mobile apps and games, this is the best place for you. Discover cheat codes, hacks, tricks and tips for applications.
The largest android library
We share only legal and safe hints and tricks. There is no surveys, no payments and no download. Forget about scam, annoying offers or lockers. All is free & clean!
No hack tools or cheat engines
Reviews and Recent Comments:
Tags:
Arc Flash Calculator Labeling cheats onlineHack Arc Flash Calculator Labeling
Cheat Arc Flash Calculator Labeling
Arc Flash Calculator Labeling Hack download