For Android: 4.0 and up | Guide: Short Circuit Fault Current cheats tutorial |
When updated: 2021-02-18 | Star Rating: 4.142857 |
Name: Short Circuit Fault Current hack for android | Extension: Apk |
Author: ARCAD INC. | File Name: com.arcadvisor.shortcircuitanalytic |
Current Version: 1.0.1 | User Rating: Everyone |
Downloads: 10000-13347 | Version: mod, apk, unlock |
System: Android | Type: Education |
Watch Overcurrent, Overload, Short Circuit, and Ground Fault video.
Watch What is the Difference Between a Short Circuit and a Ground Fault? video.
Watch What Does Available Fault Current Mean? video.
Watch Electrical Testing Measuring Prospective Fault Current PFC (How to do a PSCC and PEFC Test) video.
Watch A2 Power System : Short Circuit Calculations video.
Watch How to calculate short circuit current rating in transformer || Fault level calculation video.
Watch Short Circuit Fault Level Calculation video.
Watch Short Circuit Current Rating (SCCR) video.
Watch Short Circuit Calculations and Symmetrical Components – Part 1 video.
Watch 2020 NEC - Fault Current and Available Fault Current New Definitions video.
Short Circuit Analytic ver 1.0 mobile apk performs accessible short circuit fault current calculations in three-phase radial power system you are working with. The apk takes into consideration all of the key electrical parameters of power distribution system including power supply, cables, transformers, generators and motors. The source can be set as a transformer supply or a busbar with a specified short circuit level. If a transformer source is used, the short circuit level on the basic side can be set to infinity by setting the data field blank. Add components one by one to build up a single line diagram. The components can be cables, transformers, ligting loads, electrical devices, motors and generators. After a component has been added, its data can be edited by tapping the component when displayed on the screen. Tap on 'Run Analysis' button to calculate accessible 3-phase and phase-to-phase short circuit current values and fault X/R ratio at each busbar. Extra info about SCA V1.0 mobile and the comprehensive way for short circuit analysis Simple point-to-point short circuit fault current calculations are carried out using Ohm's law and equipment resistance values. To determine fault current at different places within power system, the system characteristics such as accessible short circuit value at service entrance, line voltage, transformer KVA rating and percent impedance, conductor characteristics are utilized. The calculations become more complicated when resistance values are replaced with an impedance values. For instance, transformer ratio of reactance to resistance (X/R) is used along with transformer percent impedance to determine X and R values on a per unit bases. Similarly, the impedance for conductors within the electrical system are also broken down into X and R components of the impedance. The peak asymmetric fault current is also determined by X/R ratio. The total asymmetric current is a measure of the total DC component and the symmetrical component. The asymmetrical component decays with time and will cause the first cycle of a fault current to be larger in magnitude than the steady-state fault current. Also, the decay of the DC component depends on the X/R ratio of the circuit between the source and the fault. Knowing the fault X/R ratio is essential when choosing electrical and safety equipment. For example, all low-voltage protective devices are inspected at predetermined X/R ratios. If the calculated X/R ratio at any given point in the electrical distribution system exceeds the inspected X/R ratio of the overcurrent protective device, alternate gear with adequate X/R rating could be considered or the device effective rating must be reduced. Features and Capabilities: 1. Calculate 3-phase, phase-to-phase short circuit currents at each bus within your power distribution system 2. Determine maximum accessible short circuit current, the amount of maximum upstream short circuit current and the minimum accessible short circuit current contributed by one source only. Both the accessible short circuit current (ASCC) and the part of ASCC through safety device current values are needed for comprehensive arc flash hazard analysis using NFPA 70E and IEEE 1584 methods 3. Compute contributions from generators and motors 4. Add North American wire gauge cables as well as international cables 5. Perform comprehensive short circuit analysis by taking into acc both active and reactive parts of equipment impedance 6. Determine fault X/R ratio at each bus 7. Save, rename, duplicate single-line diagrams and equipment data 8. Export, import one-line diagrams and all the equipment data for simple sharing 9. Send calculation results and captured single-line diagrams by email
Share you own hack tricks, advices and fixes. Write review for each tested game or app. Great mobility, fast server and no viruses. Each user like you can easily improve this page and make it more friendly for other visitors. Leave small help for rest of app' users. Go ahead and simply share funny tricks, rate stuff or just describe the way to get the advantage. Thanks!
Welcome on the best website for android users. If you love mobile apps and games, this is the best place for you. Discover cheat codes, hacks, tricks and tips for applications.
The largest android library
We share only legal and safe hints and tricks. There is no surveys, no payments and no download. Forget about scam, annoying offers or lockers. All is free & clean!
No hack tools or cheat engines
Reviews and Recent Comments:
Tags:
Short Circuit Fault Current cheats onlineHack Short Circuit Fault Current
Cheat Short Circuit Fault Current
Short Circuit Fault Current Hack download